Contact Us
- +86-28-6256-7958-8001#
- MON-FRI 09:00 - 17:30, SAT 10:00 - 17:00
- UTC +8:00 Beijing Time
WNY is a compact long-life liquid vacuum pump driven by a brushless motor with good longevity and reliability. It adopts EPDM diaphragm material and PA6 reinforced nylon pump head, which has good chemical compatibility.
Contact us for the latest product information and technical support!
WNY is a compact long-life liquid vacuum pump driven by a brushless motor with good longevity and reliability. It adopts EPDM diaphragm material and PA6 reinforced nylon pump head, which has good chemical compatibility. It has a wide range of ambient temperature tolerance and can operate reliably at ambient temperatures of 50 degrees Celsius or higher. It operates with minimal noise during work and supports flexible installation, which can reduce the impact of vibration during work on the equipment.
WNY series pump is driven by brushless motors which have the advantages of long service life, low interference and high reliability. It can run continuously for a long time, and the pumping life of the premium version can reach 12,000 hours. It offers 12V DC/24V DC options.
Equipped with overheating protection, overload protection,, which to the greatest extent prevents accidental damage to the pump.
The motor speed can be changed and the flow can be adjusted by changing the duty cycle by inputting the PWM signal. Or by ordering Hilintec special speed controller (model: TS-C24 and TS-D12) for speed regulation.
Liquid-gas dual-use, can be used as a liquid pump or a vacuum pump, can also be used to transfer gas-liquid mixed media; dry-run and self-priming.
There is no need to add lubricating oil and maintenance, and it does not pollute the medium.
Good Corrosion Resistance
The materials of the wetted parts: reinforced nylon and EPDM rubber, PP connector,Or nickel-plated copper connector, or stainless steel connector.
This liquid vacum pump can be installed in any direction, gas and liquid can be transferred normally in any installation direction.
If you need a higher flow more than 1L/min liquid pump, please check at the S36 model.
Model | WNY600A | ||
Material Option | Diaphragm: EPDM Valves: EPDM Pump Head: Fiber reinforced PA6 | Diaphragm: EPDM Valves: EPDM Pump Head: Fiber reinforced PA6 | |
Voltage(V DC) | 12 | 24 | |
As Gas Pump | Max. Load Current (mA) | ≤330 | ≤200 |
Max. Average Flow Rate (L/min) | ≥0.6 | ≥0.8 | |
Max. Vacuum (-kPa) | ≥17 | ≥17 | |
As Liquid Pump | Max. Load Current (mA) | ≤350 | ≤240 |
Free Flow Rate (L/min) | ≥0.6 | ≥0.6 | |
Max. Suction Height (mWg) | 2m | 2m | |
Flow Rate @ Max. Suction Height | 300mL/min | 300mL/min | |
Max. Pressure Height (mWg) | 4m | 4m | |
Flow Rate @ Max. Pressure Height | 280mL/min | 280mL/min |
Model | WNY1000A | ||
Material Option | Diaphragm: EPDM Valves: EPDM Pump Head: Fiber reinforced PA6 | Diaphragm: EPDM Valves: EPDM Pump Head: Fiber reinforced PA6 | |
Voltage(V DC) | 12 | 24 | |
As Gas Pump | Max. Load Current (mA) | ≤380 | ≤220 |
Max. Average Flow Rate (L/min) | ≥0.9 | ≥1.1 | |
Max. Vacuum (-kPa) | ≥27 | ≥27 | |
As Liquid Pump | Max. Load Current (mA) | ≤500 | ≤280 |
Free Flow Rate (L/min) | ≥1.0 | ≥1.0 | |
Max. Suction Height (mWg) | 3m | 3m | |
Flow Rate @ Max. Suction Height | 400mL/min | 400mL/min | |
Max. Pressure Height (mWg) | 5m | 5m | |
Flow Rate @ Max. Pressure Height | 280mL/min | 280mL/min |
Material Options | |
Pump Head | Fiber reinforced PA6 |
Diaphragm | EPDM |
Valves | EPDM |
Motor | BLDC 12V 24V |
Models | WNY600A WNY1000A | ||
Versions | Simplified | Standard | Premium |
Fully Loaded Lifetime(hrs) | 3500 | 6000 | 10000 |
Unloaded Lifetime(hrs) | 8000 | 12000 | 18000 |
Motor Lifetime(hrs) | 10000 | 15000 | 20000 |
Test conditions | In a clean and non-corrosive laboratory, the pump is fully loaded (continuous pumping water) or unloaded (the inlet and outlet are directly connected to the atmosphere), and runs continuously around the clock; ambient temperature: 5℃~33 ℃, relative humidity: 50%-85%, fluctuates with the climate. | ||
Working Condition | |||
Operating temperature | Permissible ambient temperature is 0℃~50℃, it is not suitable to be exposed to the sun, and it should work in a clean and ventilated environment | ||
Medium | Permissible temperature of the medium is 5℃~50℃ and gaseous media is 0℃~50℃, the transferring gas cannot contain solid particles or oil mist. It is not allowed to pump oily liquid and high viscosity liquid. | ||
Wetted materials | EPDM, fiber reinforced PA6 nylon, tolerance to alcohol, acid, alkali, etc. (except strong acid, concentrated acid, lipids, benzene, gasoline, etc.) |
WNY is a small diaphragm liquid vacuum pump for gas and liquid dual-purpose. It is driven by a BLDC motor.
Product SKU: S36
Product Brand: Hilintec
Product Currency: USD
Price Valid Until: 2021-11-01
Product In-Stock: InStock
We are very happy to get in touch with you and provide more information
Something isn’t Clear?
Feel free to contact us for free consultation, and we will be more than happy to answer all of your questions within 24Hours.