Smoother Airflow, More Composed Analysis — Hilintec’s Full Line of Original Low-Pulsation Gas Pumps Unveiled

Low-Pulsation

Smoother Airflow, More Composed Analysis — Hilintec’s Full Line of Original Low-Pulsation Gas Pumps Unveiled

In gas sampling and analysis systems, the value of a gas pump lies not only in how much gas it can deliver or how much pressure it can build, but also in whether it can provide a steady airflow. Rapid jitter of a flow meter’s float and frequent jumps in sensor readings may all be related to airflow pulsation. For instrument developers pursuing precision measurement, these fluctuations mean more work on gas path optimization, signal processing, and debugging.

Addressing this need, Hilin Technology has launched an original low-pulsation gas pump product line covering four major series: D09, D11, D27, and D31. From small portable devices to continuous online sampling, from micro-pressure gas delivery to sampling systems with higher load capacity, Hilin Technology offers more stable gas source options for instrument development through different structures and configurations.

Why does airflow still fluctuate even when the average flow rate meets the target?

Gas pulsation refers to the repeated fluctuation of instantaneous flow and pressure within a short period of time. Even if the average value displayed by the flow meter remains unchanged, the gas in the pipeline may be undergoing rapid “strong—weak—strong” changes. This phenomenon is different from the flow decline after long-term use.

Flow attenuation over weeks or months caused by gradual filter clogging or wear of mechanical parts is a long-term flow stability issue; whereas pulsation often occurs on a time scale of milliseconds to seconds, manifesting as rapid float jitter or periodic fluctuations in sensor signals. Therefore, when selecting a sampling pump, in addition to average flow and pressure, attention should also be paid to whether the instantaneous airflow is sufficiently steady.

Where does the pulsation of traditional diaphragm pumps come from?

Traditional single-chamber diaphragm pumps rely on the reciprocating motion of a diaphragm to transport gas. When the pump chamber volume increases, gas enters the pump chamber through the inlet valve; when the pump chamber volume decreases, the gas is compressed and discharged through the outlet valve. Suction and discharge alternate, and the instantaneous delivery volume of a single pump chamber continuously changes within one working cycle, thereby forming periodic flow and pressure fluctuations.

This pulsation originates from the working principle of single-chamber positive displacement pumps and continues to occur while the pump is running continuously. For example, when the working cycle is 3,000 times per minute, the corresponding fundamental motion frequency is 50 Hz. Such rapid fluctuations may be difficult to see from the average readings of ordinary instruments, but they will appear in the signals of fast-response flow or pressure sensors.

What challenges does airflow pulsation bring to precision analysis?

The first is fluctuation in measurement signals. In gas analysis systems, flow, pressure, and detection signals sensitive to airflow conditions may all be affected by pulsation, making it more difficult to obtain stable readings and to process data afterward. The second is the burden on gas path design. To smooth out fluctuations, engineers often need to add buffer volumes, throttling elements, or dedicated flow stabilizers.

Buffer volumes require extra space and may prolong gas replacement time; throttling elements introduce resistance, causing flow loss, and small channels also need attention to dust clogging; flow stabilizers also require corresponding installation positions, connecting pipelines, and component costs. In addition, airflow pulsation may also cause pipeline noise and vibration, subjecting gas path components to periodic loads and affecting the operating quality of the equipment. For portable instruments with limited space, and online analysis equipment that needs to balance response speed, measurement stability, and integration cost, reducing source pulsation has direct design value.

Multi-chamber coordination reduces pulsation from the airflow source

Hilintec changes the intermittent delivery output characteristics of traditional single-chamber pumps through a multi-chamber coordinated design. The D09 adopts a three-pump-chamber structure, and the D27 and D31 adopt a five-chamber coordinated structure. Multiple pump chambers work in coordination at different phases, and the instantaneous flows of the chambers superimpose, causing the output waveforms to compensate each other, reducing airflow pulsation at the suction and discharge ends and making the total airflow more continuous and smooth. This approach integrates flow stabilization capability into the gas pump itself.

System designers can, according to actual working conditions, reduce dependence on additional buffer and damping elements, creating conditions for simplifying the gas path, saving installation space, and reducing debugging burden. Hilin Technology’s “White Paper on Gas Pulsation Elimination Technology” presents the instantaneous flow test of the D27 five-chamber coordinated gas pump: in the simplified test gas path shown, without additional gas path flow stabilization optimization, the output curve of the gas mass flow sensor already shows steady characteristics, and periodic pulsation is significantly suppressed.

For micro-pressure and low-load requirements, the D11 adopts a working method different from traditional diaphragm pumps, with no mechanical rotating or transmission components inside, providing another airflow delivery option for small devices with a thin structure and extremely low flow pulsation.

Four major series covering the gas source needs of different instruments

D09: Providing compact, low-power gas sources for portable devices

Every bit of space and every bit of power in portable instruments must be carefully budgeted. The D09 integrates a three-chamber low-pulsation design into a compact pump body. Some brushed motor configurations weigh about 25 g and measure about 43.5 × 19 × 19 mm, suitable for integration into small devices and handheld sampling devices. The series offers brushed, coreless brushless, and other brushless motor configurations.

Among them, the brushed wide-voltage models can operate in the 1–6 V range, and the coreless brushless models can operate in the 3–6 V range, making it easy to match different power supply schemes. Some coreless brushless configurations can achieve a working point of 0.4 L/min flow and about 0.4 W power consumption, providing an option for applications that value battery life. Depending on the model and configuration, PWM speed control, speed feedback, or silent-type products can also be selected, finding a combination suitable for the device among size, power consumption, control, and operating sound.

D11: Precision micro-pressure delivery for thin devices

The D11M is about 10 mm thick, with an overall size of about 40 × 35 × 10 mm and a weight of about 30 g, suitable for devices sensitive to thickness and weight. At rated voltage, its nominal flow rate is 0.9 L/min, and the flow rate can be adjusted by adjusting the input voltage. With a working method different from traditional diaphragm pumps, the D11 has extremely low flow pulsation and is suitable for micro-pressure, low-load gas delivery occasions. For applications with low gas path resistance that emphasize thin integration and steady airflow, the D11 provides a targeted choice. When selecting, gas path resistance, medium cleanliness, and filtration maintenance requirements should also be considered.

D27: Meeting various sampling needs with five-chamber coordination

The D27 adopts a five-chamber coordinated structure and offers models such as D27S, D27E, D27M, and D27Q, covering different flow, power supply, and load requirements. The D27S offers a 3–6 V wide-voltage power supply option with a nominal flow rate of 2.0 L/min; the D27E is aimed at backend suction applications with a nominal flow rate of 3.7 L/min; the D27M supports both suction and pumping with a nominal flow rate of 4.0 L/min;

the D27Q has a nominal flow rate of 3.5 L/min, providing a supplement for different integration needs. The corresponding brushless configurations support PWM speed control and speed feedback, making it easy for the host controller to adjust airflow and monitor operating status. The gas transmission method that requires no lubricating oil also helps meet the sampling system’s requirements for medium cleanliness.

D31: Balancing steady airflow and continuous operation needs

The D31 also adopts a five-chamber coordinated design and offers D31M and D31Q models with nominal flow rates of 4.0 L/min and 3.5 L/min respectively, equipped with 12 V and 24 V brushless motor options, and provides PWM speed control and speed feedback functions. The D31M offers a simplified version, standard version, and quality version, which can be selected according to the device’s load capacity, continuous operation, and integration needs.

The quality version uses an aluminum alloy pump head and provides an M6 internal thread connector configuration, making it easy to match different gas path connection methods. According to the laboratory test conditions specified in the manual, the D31M quality version has a full-load life of 8,000 hours and a no-load life of 12,000 hours, providing a selection reference for instrument development that values continuous operation. The allowable output pressure differs among different versions, and the configuration should be confirmed in combination with the actual working point.

Find the right steady gas source according to application needs

ProductCore featuresKey matching needs
D09Three-chamber low pulsation, small size, low power consumption, multiple motor configurationsPortable sampling, handheld devices, battery-powered devices
D11Thin and lightweight, extremely low pulsation, precision micro-pressure deliveryLow-resistance gas paths, thin instruments, micro-pressure gas delivery
D27Five-chamber coordination, multiple flow and motor optionsBackend suction, suction/pumping dual use, diversified sampling systems
D31Five-chamber coordination, multiple quality versions, speed control and feedbackContinuous online sampling, devices requiring matching of different loads and connection methods

Product selection requires comprehensive consideration of working-point flow, inlet and outlet loads, power supply, space, medium compatibility, and control method. The flow rates in the table and text are specification values under the rated conditions of the corresponding models and do not mean that the same flow rate can still be maintained under ultimate vacuum or maximum output pressure; the low-pulsation effect also needs to be verified in combination with actual pipelines and working conditions.

Let steady airflow become the starting point of instrument design

From the compact low power consumption of the D09, to the thin micro-pressure delivery of the D11, and then to the five-chamber coordinated sampling solutions of the D27 and D31, Hilin Technology integrates low-pulsation capability into gas pumps of different specifications, providing richer gas source options for precision instrument development. Reduce source fluctuations, make measurement signals easier to obtain, make gas path design simpler, and make analysis work more composed. Hilin Technology looks forward to exploring low-pulsation airflow solutions suitable for practical applications together with instrument developers. To learn more about product details, please visit Hilin Technology’s low-pulsation pump product page, or contact the technical team to obtain product manuals, technical white papers, and selection support.

Need Help?

I’m Here To Assist You

Something isn’t Clear?


Feel free to contact us for free consultation, and we will be more than happy to answer all of your questions within 24Hours.